CVD 1200 |
|
(2) 26AWG Coax, (2) 26AWG Shielded Twisted Pairs and (7) 26AWG Wires |
|
|
|
 |
|
 |
|
|
 |
|
|
|
Element 1 |
Coaxes
Dielectric
Outer Shield
Inner Shield
Jacket
Number of Coaxes
Color Code |
26 AWG (7/34) Tinned Copper, Stranded Natural Foamed Polyolefin Propylene, 0.072” ± 0.002” Diameter
Aluminum (In) / Polyester, 25% min. Overlap
38 AWG Tinned Copper, 95% min. Coverage
Polyvinyl Chloride, 0.0085” Wall Thickness, 0.102” ± 0.005” Diameter
3
1. Red, 2. Green, 3. Blue |
|
|
|
|
Element 2 |
Twisted Pairs
Shield
Jacket
Number of Pairs Color Code
|
26 AWG (7/34) Tinned Copper, Stranded Individually Shielded Twisted Pairs
Braided, 38 AWG Tinned Copper, 85% Coverage. Polyester Tape, 25% Overlap
Polyvinyl Chloride, 0.100” +/- 0.005” Diameter
2
1. Red & Black 2. White & Black |
|
|
Element 3 |
|
Conductors
Jacket Number of Conductors
Color Code |
26 AWG (7/34) Tinned Copper, Stranded
Polyvinyl Chloride, 0.033” +/- 0.002” Diameter
7
1. Blue, 2. Green, 3. Violet, 4. Gray, 5. Yellow, 6. Orange, 7. Brown
|
|
|
|
 |
|
|
|
Conductors
Outer Shield
Inner Shield
Drain Wire
Jacket
Final Diameter
Color |
Elements 1, 2 & 3
36 AWG Tinned Copper, 85% Coverage
Aluminum (Out) / Polyester Tape, 25% Overlap
22 AWG (7/30) Tinned Copper, Over Tape
Polyvinyl Chloride, 0.042” Wall Thickness
0.350” +/- 0.010”
Black |
|
|
|
 |
|
Nominal attenuation |
|
|
Frequency (MHz)
|
Attenuation dB/100 ft. (30.48 m) |
50
100
200
400
750
1000 |
-3.656
-5.362
-7.675
-11.468
-14.876
-17.862 |
|
|
|
 |
|
Type CL2 as Specified in Article
725 of the National
Electric Code. |
|
|
 |
|
|
|
|
|
Return to the previous