Home | About Us | Contact Us | News & Events | Request Catalog | Search

 

 

 
 

CVD 3200

Plenum (3) 26AWG Coax, (2) 26AWG Shielded Twisted Pairs
and (7) 26AWG Wires

 
Element 1
Coaxes
Dielectric
Outer Shield
Inner Shield
Jacket
Number of Coaxes
Color Code
26 AWG (7/34) Tinned Copper, Stranded
Natural Foamed Fluorinated Ethylene Propylene, 0.072” ± 0.002” Diameter
Aluminum (In) / Polyester Tape, 25% Overlap
38 AWG Tinned Copper, 95% Coverage
Polyvinal Chloride, 0.008” Wall Thickness 0.100” ± 0.005” Diameter
3
1. Red, 2. Green, 3. Blue

Element 2
Twisted Pairs
Shield
Jacket
Number of Pairs
Color Code
26 AWG (7/34) Tinned Copper, Stranded Individually Shielded Twisted Pairs
Braided, 38 AWG Tinned Copper, 85% Coverage. Polyester Tape, 25% Overlap
Polyvinyl Chloride, 0.033” +/- 0.002” Diameter
2
1. Red & Black 2. White & Black

Element 3
Conductors
Jacket
Number of Conductors
Color Code
26 AWG (7/34) Tinned Copper, Stranded
Polyvinyl Chloride, 0.033” +/- 0.002” Diameter
7
1. Blue, 2. Green, 3. Violet, 4. Gray, 5. Yellow, 6. Orange, 7. Brown

Conductors
Outer Shield
Inner Shield
Drain Wire
Jacket
Final Diameter
Color
Elements 1, 2 & 3
38 AWG Tinned Copper, 85% Coverage
Aluminum (Out) / Polyester Tape, 25% Overlap
22 AWG (7/30) Tinned Copper, Over Tape
Polyvinal Chloride, 0.022” Wall Thickness
0.309” +/- 0.010”
Black
Nominal attenuation
Frequency (MHz) Attenuation dB/100 ft. (30.48 m)
50
100
200
400
750
1000
-3.60
-5.10
-7.40
-11.0
-15.9
-17.0
Type CL2P as Specified in Article 725 of the National Electric Code.
 