Home | About Us | Contact Us | News & Events | Request Catalog | Search

 

 

 
 

CVD 3900 18

Plenum (6) 26AWG Coax,
(4) 22AWG Shielded Twisted Pairs
and (4) 20AWG Wires

 
Element 1
Coaxes
Dielectric
Outer Shield
Inner Shield
Jacket
Number of Coaxes
Color Code
26 AWG (7/34) Tinned Copper, Stranded
Natural Foamed Fluorinated Ethylene Propylene, 0.072” Diameter
Aluminum (In) / Polyester Tape, 25% Overlap
38 AWG Tinned Copper, 95% Coverage
Fluorocopolymer, 0.010” Wall Thickness
0.102”
6
1. Red, 2. Green, 3. Blue, 4. Black, 5. White, 6. Yellow

Element 2
Twisted Pairs
Shield
Drain Wire
Jacket
Final Diameter
Number of Pairs
Color Code
22 AWG (7/30) Tinned Copper, Stranded Individually Shielded Twisted Pairs
Aluminum (In) / Polyester Tape, 25% Overlap
22 AWG (7/30) Tinned Copper
Fluorocopolymer, 0.010” Wall Thickness
0.110”
4
1. Red & Black, 2. White & Black, 3. Green & Black 4. Orange & Black

Element 3
Conductors
Insulation
Final Diameter
Number of Coaxes
Color Code
20 AWG (7/28) Tinned Copper, Stranded
Polyvinyl Chloride,
0.051”
4
1. Red, 2. White, 3. Black, 4. Green

Conductors
Drain Wire
Jacket
Final Diameter
Color
Elements 1, 2 & 3
24 AWG (7/32) Tinned Copper
Polyvinyl Chloride
0.450”
Dark Blue
Nominal attenuation
Frequency (MHz) Attenuation dB/100 ft. (30.48 m)
50
100
200
400
750
1000
-3.60
-5.10
-7.40
-11.0
-15.9
-17.0
Type CL2P as Specified in Article 725 of the National Electric Code.
 
 CVD 3900 18 Spec Sheet
 
Return to the previous page.

 

800.638.6104

 

sales@covid.com